Baseline units must support both W and Wh

    • Type: Bug
    • Resolution: No Action
    • Priority: Major
    • wd29
    • Affects Version/s: CSD02/PR02
    • Component/s: schema
    • None
    • Environment:

      Bartell

    • Hide

      PowerReal (which should really be RealPower) is hanging off of EventBaseLineType and not contributing much. Move it to be a choice or in a substitution group with energyReal (which should be RealEnergy) in eventBaselineDescription.

      Show
      PowerReal (which should really be RealPower) is hanging off of EventBaseLineType and not contributing much. Move it to be a choice or in a substitution group with energyReal (which should be RealEnergy) in eventBaselineDescription.
    • Hide

      In WD29 WIP2, Baselines moved to be based on ItemBase, which is the parent type for both Real Power, Real Energy, and a number of other things that might warrant baselining and measuring.

      This supports (when baselines are finished) W, Wh, as well as SI J/s and J.

      Check units and type names for correctness.

      Show
      In WD29 WIP2, Baselines moved to be based on ItemBase, which is the parent type for both Real Power, Real Energy, and a number of other things that might warrant baselining and measuring. This supports (when baselines are finished) W, Wh, as well as SI J/s and J. Check units and type names for correctness.

      Baseline calculations use either Power (W) or Energy (Wh) depending on whose program it is.

      PJM uses an average kW at one-minute interavals. California Edison uses KWh per hour. NYISO uses MWh per hour.

      See also ENERGYINTEROP-497 and ENERGYINTEROP-498

            Assignee:
            Toby Considine (Inactive)
            Reporter:
            Bruce Bartell (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue

              Created:
              Updated: