Uploaded image for project: 'OASIS Message Queuing Telemetry Transport (MQTT) TC'
  1. OASIS Message Queuing Telemetry Transport (MQTT) TC
  2. MQTT-331

Clearing comments from the V5 specification.

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: 5
    • Fix Version/s: wd11
    • Component/s: edits
    • Labels:
      None
    • Proposal:
      Hide

      3.1.2.14 Receive Maximum

      • Added a new DISCONNECT return code 147 Receive Maximum exceeded.
      • Added a new DISCONNECT return code 148 Topic Alias invalid.

      3.1.2.18 Request Problem Info

      • It is a protocol error for the server to send a client Problem Info
        where the client has set Request Problem Info to 0.

      3.14.2.1 Disconnect Return Codes

      • 153 0x99 Disconnect with Will message
        changed to
        4 0x04 Disconnect with Will message.
      Show
      3.1.2.14 Receive Maximum Added a new DISCONNECT return code 147 Receive Maximum exceeded. Added a new DISCONNECT return code 148 Topic Alias invalid. 3.1.2.18 Request Problem Info It is a protocol error for the server to send a client Problem Info where the client has set Request Problem Info to 0. 3.14.2.1 Disconnect Return Codes 153 0x99 Disconnect with Will message changed to 4 0x04 Disconnect with Will message.

      Description

      Resolve comments added to the MQTT V5 specification.