• Type: Bug
    • Resolution: Fixed
    • Priority: Major
    • ODF 1.2
    • Affects Version/s: None
    • Component/s: OpenFormula
    • None
    • Hide

      In the table of CONVERT mark the following units with a '*' asterisk to indicate support of SI prefixes:
      "ang"
      "ang3"
      "m/h", "m/hr"

      Show
      In the table of CONVERT mark the following units with a '*' asterisk to indicate support of SI prefixes: "ang" "ang3" "m/h", "m/hr"
    • Hide

      Applied proposal.

      Show
      Applied proposal.

      Existing implementations of the CONVERT function know SI prefixes for the length unit "ang", the draft omits it in the definition; note that "ang2" allows SI prefixes.
      Additionally, "ang3" and "m/h" respectively "m/hr" should support prefixes.

            Assignee:
            Eike Rathke (Inactive)
            Reporter:
            Eike Rathke (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue

              Created:
              Updated:
              Resolved: